For peak transformer performance and optimal oil quality, rely on the FA-ST Transformer Oil Analysis Service. This solution enables proactive monitoring of oil condition, ensuring crucial factors such as insulation and dielectric properties align with industry standards. FA-ST delivers a comprehensive range of analysis services tailored to your specific needs, simplifying the process of oil monitoring.
Our diverse testing suites provide in-depth insights into your transformer's well-being, guaranteeing precise analyses. Regular testing instills confidence in both your oil and transformer's functionality. Whether you require DGA & PCB testing, water content monitoring, or specialised analyses, our service have you covered.
Excitingly, we now incorporate furfuraldehyde analysis into our service offerings.
Our core set of transformer oil tests is crafted to provide essential insights, ensuring the optimal functioning of your transformer. In situations where transformers face issues like electrical arcing or a decline in the essential properties of the oil required for peak performance, having a variety of testing options becomes imperative for early detection of potential problems.
We offer three fundamental testing suites:
This is the most comprehensive test conducted by FA-ST on transformer oils. Encompassing a broad spectrum of factors, from aging oils to paper insulations degradation, this analysis is indispensable for anyone seeking an exceptionally thorough comprehension of potential issues with their system.
This is a widely favored test conducted on transformers. These examinations efficiently pinpoint transformer issues at an affordable rate. They reveal crucial factors like elevated acidity levels that can result in tank corrosion, oil degradation, and other critical concerns.
These assessments offer insights into the overall operational status of the transformer. They have the capability to gauge the presence of fault gases within the system, which may trigger problems like sparking, overheating and arcing, while also detecting potential component breakdowns.
Tailoring the analysis of transformer oils to address specific issues may not always require a comprehensive approach. Targeted monitoring of individual oil aspects can be achieved through standalone testing, catering to the specific needs of your situation.
Explore our addition transformer testing options below:
The accumulation of water in transformer oils is a widely recognised issues with the potential to impede transformer performance. Challenges related to the oil's insulating abilities, impacts on dielectric properties, and accelerated oil aging should all be taken into account when assessing water levels.
The longevity of well-maintained transformers without significant defects can hinge on the quality of their paper insulation. Furfuraldehyde, a degradation byproduct, has the potential to impact the paper's structural integrity, making it brittle and ultimately leading to the end of the transformer's usable life.
In the past, PCBs were commonly used as an insulating fluid in many mineral oil transformers. PCBs can infiltrate new systems through cross-contamination from previously used equipment in these tanks. To facilitate the safe reuse of these oils. it is essential to reduce PCB content to levels below 10mg/kg.
Widely acknowledged as the earliest method as the earliest method for detecting emerging faults transformers and tap selector units, DGA analysis is a vital tool for understanding the thermal and electrical stress experienced by transformer oils. Through the monitoring of gases such as nitrogen, oxygen, carbon monoxide, methane, and various others. DGA analysis is adept at detecting abnormal conditions that may affect the transformer, including particle discharge, arcing, and excessive thermal stress. Safeguard your transformer against gas buildup with our DGA analysis service.
Our routine analysis is conducted to offer a fundamental evaluation of the transformer and its operational oil. This analysis serves as an ideal choice for those seeking a basic comprehension of their transformer's condition and an early identification of potential issues before implementing corrective measures. The routine transformer oil test suite provides essential information through visual inspection, assessment of acidity levels, estimation of fiber content, evaluation of electrical strength, measurement of water content, and determination of resistivity.
Secure on line payments can be made by Credit/Debit Card via SAGEPAY or PayPal
Orders and payments can also be made by telephoning our office on
+44 (0) 1246268900
Tel: +44 (0)1246268900 Email: webshop@fa-st.co.uk
Works, Office, Warehouse & Postal Address
FA-ST Filtration Analysis Services Technology Ltd,